13
4. Wand emulation
To perform Wand Emulation, the scanner can be connected
to a portable data terminal, or a controller that collects the
data as wand data, and interprets it for the host.
1.) Make sure that the power of your computer system is
switched off.
2.) Plug the interface cable modular into the scanner port
until a firm
“Click” sound is heard.
3.) Connect the other end of the interface cable into the
COM port on the PDT or controller.
4.) Use a power +5V DC external power supply to the
power jack on the interface cable if the external power is
required.
5.) Switch on your computer system
6.) Adjust the scanner’s parameters by scanning the
appropriate labels in programming guide, if necessary.
It is our advice to turn off your POS or host system
before starting the installation of the scanner. By
following this procedure you can avoid from being
electronically damaged to your computer.
It is also our advice to install the scanner in an
air-circulated place but away from the direct sunlight.
Use only AC/DC power adaptor approved for the
Z-6070 scanner that ordered from ZEBEX. Usage of
other power supplies may cause damage to the
product, and the damage is not covered by the factory
warranty.
Kommentare zu diesen Handbüchern